Page | 001 CELLS STATE PER RD SQTATE PER RD, NEW LONDON, CT 06320 4,896KW/19,584KWH BATTERY ENERGY STORAGE SYSTEM SITE SYSTEM SPECIFICATION - BESS TESLA MEGAPACK 2XL QTY 5 KW 979.2 KWH 3916.8 TOTAL 5 4896 19584 • • • '- ' SHEET NUMBER E.000 E.001 E.002 E.O10 .011 E.O12 E.O13 E.101 . 10 E.120 E.210 E.220 E.300 E.400 E.401 S.000 E.500 E.501 E.502 E.503 SHEET TITLE TITLE PAGE GENERAL LEGEND DETAILS 01 AlS 2 DETAILS 03 DETAILS 04 CONDUIT PLAN SITE VICINITY PLAN GND CALCS SIGNAGE 01 SPECS 01 SPECS 02 STRUCTURAL SITE VICINITY MAP ENVIRONMENTAL RESOURCES ENVIRONMENTAL RESOURCES 2 ENVIRONMENTAL RESOURCES 3 .- -- --- - --- - ------ - --- --- APPLICABLE CODES: 1. 2020 NATIONAL ELECTRIC CODE (NEC) 2. 2021 INTERNATIONAL BUILDING CODE (IBC) N N 3. 2022 CONNECTICUT STATE FIRE SAFETY CODE - BASED ON 2021 INTERNATIONAL FIRE CODE (IFC) 4. 2023 NFPA 855 5. 2022 NFPA 110 6. 2022 NFPA 111 7. 2023 NESC PROJECT TEAM ENGINEER: HENRY HOLBROOK HYDE Ill HYDE RENEWABLES, INC. 4735 WALNUT STREET, SUITE #110 BOULDER, CO 80301 WWW.HYDERENEWABLES.COM P: (720) 900-1 009 SCOPE OF WORK INSTALLATION OF A NEW BATTERY ENERGY STORAGE SYSTEM AND ASSOCIATED EQUIPMENT. THE SYSTEM WILL BE INTERCONNECTED IN AN EXISTING MEDIUM VOLTAGE UTILITY VAULT. / ' 1111,, HYDE 1111., �v���!!!��u�c! QCells Completely Clean Energy THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PREPARED BY HYDE RENEWABLES, INC. FOR THEIR EXCLUSIVE USE IN ACCORD WITH TITLE 20 SEC. 20-300-10 OF THE CONNECTICUT ADMINISTRATIVE CODE. ,1\\\\\\\l\l lllll/JU//1111, ✓ '�\\\a�. _c? �-'!f:;; ❖1,,�1- .f ,<,,_\...-Q\..BROo··.. � %, if"'....,,_ Ji�.·0 !!li'r �� 't ,;,_,_... .A% !•�!��!•I . f� ··f No. 32042 �-: $j %� ···./lcfNSSQ ..... �j 3⁄4/.�& ·-........-·· 0'"'# �,:,,,,,}ltoNAL 't:-�,�«- lfl///f/f/11111111\I\I\I\IX SCALE: AS NOTED (PRINT ON 36"X24") FK N REDESIGN 06/26/24 RK M AHJ 03/13/23 COMMENTS AR L 90% 01/03/24 RK K REDLINES 12/07/23 RK J 60% UPDATE 10/05/23 RK H 60% UPDATE 7/31/23 RK G 60% UPDATE 07/27/23 ST F REDLINES 06/12/23 ST E REDLINES 05/23/23 CB D 60% 05/11/23 CB C 30% 04/12/23 CB B INTXN DRAFT 02/09/23 2 CB A INTXN DRAFT 1 02/08/23 ,BY REV ISSUE DATE FIRM NAME AND ADDRESS HYDE RENEWABLES, INC 4735 WALNUT ST, SUITE #110 BOULDER, CO 80301 INFO@HYDERENEWABLES.COM 720-900-1009 WWW.HYDERENEWABLES.COM PROJECT NAME AND ADDRESS Q CELLS STATE PIER RD STATE PIER RD NEW LONDON, CT 06320 LAT=N 41" 21'38.4" LON=W 72" 05'56.0" (_P_R_oJ_E_cT_#_: _0_69_ -_ 1_0_00_ ___) SHEET TITLE TITLE PAGE / DRAWN BY CB CHECKED BY , TRIPP HYDE SHEET # ' E.000 DATE 02/08/23 |