Search Completed | Title | Fire Hazard and Risk Assessment Battery Energy Storage System (BESS)
Original File Name Searched: BESS-Amendment-Fire-Hazard-Risk-Assessment.pdf | Google It | Yahoo | Bing

Page | 078 BAL – AS3959 – Construction Requirements BAL – FZ Subfloor supports – enclosure by external wall or non-combustible with an FRL of 30/-/- or be tested for bushfire resistance to AS1530.8.2 Concrete slab on ground or enclosure by external wall or an FRL of 30/30/30 or protection of underside with 30 minute incipient spread of fire system or to be tested for bushfire resistance to AS1530.8.2 Non-combustible material (masonry, brick veneer, mud brick, aerated concrete, concrete) with minimum thickness of 90mm or an FRL of -/30/30 when tested from outside or be tested for bushfire resistance to AS1530.8.2 Protected by bushfire shutter or FRL of -/30/- and openable portion screened with steel or bronze mesh or be tested for bushfire resistance to AS1530.8.2 SUBFLOOR SUPPORTS FLOORS EXTERNAL WALLS BAL – LOW No special construction requirements No special construction requirements No special construction requirements No special construction requirements BAL – 12.5 No special construction requirements No special construction requirements As for BAL–19 BAL – 19 No special construction requirements No special construction requirements External walls – Parts less than 400m above ground or decks etc to be of non-combustible material, 6mm fibre cement clad or bushfire resistant/naturally fire resistant timber Protected by bushfire shutter, completely screened with steel, bronze or aluminium mesh or 5mm toughened glass or glass blocks within 400mm of ground, deck etc. Openable portion metal screened with frame of metal or metal reinforced PVC-U or bushfire resisting timber BAL – 29 Enclosure by external wall or by steel, bronze or aluminium mesh, non-combustible supports where the subfloor is unenclosed, naturally fire resistant timber stumps or posts on 75mm metal stirrups Concrete slab on ground, enclosure by external wall, metal mesh as above or flooring less than 400mm above ground level to be non-combustible, naturally fire resistant timber or protected on the underside with sarking or mineral wool insulation Non-combustible material (masonry, brick veneer, mud brick, aerated concrete, concrete), timber framed, steel framed walls sarked on the outside and clad with 6mm fibre content sheeting or steel sheeting or bushfire resisting timber Protected by bushfire shutter, completely screened with steel, bronze or aluminium mesh or 5mm toughened glass or glass with openable portion metal screened and frame of metal or metal reinforced PVC-U or bushfire resisting timber and portion within 400mm of ground level screened. BAL – 40 If enclosed by external wall refer below ‘External Walls’ section in table or non- combustible subfloor supports or tested for bushfire resistance to AS1530.8.1 Concrete slab on ground, enclosed by external wall or protection of underside with non-combustible material such as fibre cement sheet or be non-combustible or be tested for bushfire resistance to AS1530.8.1 Non-combustible material (masonry, brick veneer, mud brick, aerated concrete, concrete), timber framed, steel framed walls sarked on the outside and clad with 9mm fibre content sheeting or steel sheeting or be tested for bushfire resistance to AS1530.8.1 Protected by bushfire shutter or 5mm toughened glass. Openable portion screened with steel or bronze mesh. EXTERNAL WINDOWS As for BAL-19 except that 4mm Grade A safety glass can be used in place of 5 mm toughened glass |